EasyManua.ls Logo

NTI Audio XL2 - Appendix 2: Factory Default Profiles

NTI Audio XL2
204 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
190
Appendix
Appendix 2: Factory Default Profiles
You may start up the XL2 with individual preset application pro-
files.
The profile Full mode is the default configuration with all avail-
able measurement functions enabled.
DIN15905-5 / DIN15905-5 & Audio
(Sound Level Monitoring in accordance with DIN15905-5)
The following limits apply at all areas accessible by the visitors
during the measurement period of 30 minutes:
Maximum averaged level = 99 dB •
The XL2 displays this maximum level with the measure-
ment result L
Aeq+k1
.
Maximum peak level L•
Cpeak
= 135 dB