Rev 6.7 January 2023 8
of microorganisms. Make-up air inlets and exhaust air outlets shall be located to avoid contamination of
the makeup air. Contaminants from sources such as cooling towers, sanitary vents, vehicular exhaust,
and street traffic should be avoided. Consult local code requirements for minimum distances.
Mounting & Noise Control
For maximum efficiency, the HRV should be installed in a heated area. The HRV is designed to be hung
from the ceiling by way of the anti-vibration straps supplied. Avoid hanging the HRV directly below a
bedroom or other quiet area. Your unit comes with Nu-Air EZ-Level adjustable hanging straps for easy
mounting and leveling.
2.5.1. Connecting To Other Equipment - Residential Applications
Interconnection with a forced air furnace duct system is permissible; however, your HRV is not intended
to be connected to any other equipment or appliances.