EasyManua.ls Logo

NUK Simply Natural Freemie User Manual

NUK Simply Natural Freemie
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User Manual for NUK
®
Simply
Natural
Freemie
®
Mobile Pump
IMPORTANT - Read this manual prior to use.
Please save this manual.
Review the most current manual at www.nuk-usa.com
or www.freemie.com
This manual contains important information for the proper sanitization, use and care of
your NUK Simply Natural Freemie breast pump system. Please visit www.Freemie.com,
for customer service and all your spare parts needs.
Double Electric Breast Pump

Other manuals for NUK Simply Natural Freemie

Question and Answer IconNeed help?

Do you have a question about the NUK Simply Natural Freemie and is the answer not in the manual?

NUK Simply Natural Freemie Specifications

General IconGeneral
BrandNUK
ModelSimply Natural Freemie
MaterialBPA-Free Plastic
TypeCollection Cups
Capacity8 oz
FeaturesHands-free, discreet

Summary

Intended Use and Product Overview

Intended Use

Defines the product's purpose as a breast pump for lactating women.

Contraindications for Use

Lists any known conditions or situations where the breast pump should not be used.

Product Description

Details the features, capabilities, and design of the NUK Simply Natural Freemie pump.

Important Notice

Provides a critical advisory for users to read the manual before operation and save it.

Important Safety Instructions

Electrical Safety Guidelines

Warnings regarding electrocution, proper power usage, and handling electrical components.

Device Hazard Warnings

Safety rules to prevent damage, shock, fire, and injury during pump operation.

Health & Injury Prevention

Precautions to avoid health risks and personal injuries while using the breast pump.

Further Safety Guidelines and Usage Advice

Component Inspection and Maintenance

Instructions for checking parts for damage and procedures for cleaning and drying.

Proper Usage and Compatibility

Guidance on usage frequency, compatibility with other products, and professional consultation.

Child Safety and Health Precautions

Warnings for keeping the pump away from children and considerations for mothers with certain health conditions.

NUK Simply Natural Freemie Pump Systems Components

Collection Components Overview

Lists and illustrates the various parts of the Freemie collection system.

Connection Kit and Accessories

Details the connection kit and other included accessories for the pump system.

Pump Unit Components

Identifies and describes the main parts of the NUK Simply Natural Freemie pump unit.

Pump the Freemie Way: Usage Scenarios

Efficient and Discreet Pumping

Advice on how to pump efficiently, discreetly at work, or while traveling.

Pumping for Comfort and Bonding

Guidance on using the timer for relaxed pumping and pumping while bonding with baby.

Freemie Cup Features

Highlights key features of the Freemie Collection Cup, including overflow protection.

NUK Simply Natural Freemie Breast Pump Features

Customizable Memory Settings

Allows users to create and save personalized suction and speed patterns for stimulation and expression.

User Interface and Controls

Details the backlit LCD screen, power button, suction/speed adjustment keys, and timer.

Ports and Charging

Information on the tubing connection port and the micro USB charging port.

Included Pump Accessories

Lists the accessories provided with the NUK Simply Natural Freemie Mobile Pump system.

Preparing NUK Simply Natural Freemie Pump for First Use

Initial Battery Charging

Instructions for fully charging the pump's non-replaceable lithium-ion battery before first use.

Battery Operation Time

Information on expected battery life and the possibility of using the pump while charging.

Travel with Lithium-Ion Batteries

Advice on checking country restrictions for lithium-ion batteries when traveling.

Sanitizing Freemie Collection Cups for First Use

Sanitization Method Warnings

Caution against steam sterilizing or dishwashing parts, which can cause warping and void warranty.

Boiling Component Instructions

Detailed steps for boiling specific parts for 10 minutes to sanitize them effectively.

Hand Washing Component Instructions

Instructions for hand-washing parts that should not be boiled, using soap and water.

Regular Cleaning After Each Use

Component Disassembly and Washing

Steps to disassemble and wash all components that come into contact with breast milk.

Inspection and Drying Procedures

Guidance on inspecting parts for damage and ensuring they are completely dry after washing.

Storage of Cleaned Parts

Recommendations for storing parts after cleaning, including avoiding refrigeration of assembled parts.

Assembling Freemie Collection Cups

Collection Cup Assembly Steps

Step-by-step instructions for assembling the barrier, valve base, valve, and cup.

Ensuring Secure Assembly

Tips for achieving a proper fit, hearing a 'snap', and confirming secure connections.

Connecting to Your NUK Simply Natural Freemie Pump

Single and Double Pumping Setup

Illustrates how to connect tubing for single and double pumping configurations.

Assembly Verification Check

Method to check correct assembly by observing barrier movement when the pump is running.

Attaching and Removing Your Belt Clip

How to Attach the Belt Clip

Instructions on sliding and snapping the belt clip into the pump's slot for secure attachment.

How to Remove the Belt Clip

Step-by-step guide to disengage and slide the belt clip away from the pump.

Positioning Within Your Bra

Finding the Ideal Bra Fit

Emphasizes the importance of bra fit for effective hands-free pumping and optimal cup placement.

Nipple Alignment and Funnel Sizing

Ensures the nipple is centered in the funnel and provides guidance on checking for pain or pinching.

Breast Funnel Fit and Sizing

Assessing Funnel Fit for Comfort

Key points to check, like nipple rubbing, areolar blanching, and pain, to determine fit.

Understanding Correct Funnel Size

Visual comparison of too small, too large, and correct funnel sizes for optimal pumping.

Funnel Internal Diameter

Explains that internal diameter is measured across the opening of the breast funnel.

Cup Positioning and Orientation for Pumping

Tubing Port at 12 O'Clock Position

Specifies that the tubing port and pour spout should be oriented at the 12 o'clock position.

Correct vs. Incorrect Placement

Illustrates correct upright positioning for milk flow versus incorrect positions causing spillage.

Pumping Position Guidelines

Optimal Collection Cup Placement

Shows ideal positions for collection cups relative to the horizon for efficient milk flow.

Pumping Position Risks and Variations

Illustrates 'okay', 'may cause milk to spill', and 'incorrect' positions for cups.

Pump Controls and Display Indicators

Pump Control Buttons Explained

Identifies and describes the function of each button on the pump control panel.

Understanding Display Indicators

Explains the meaning of the LCD screen elements like suction/speed settings, battery meter, and timer.

Pumping with Your NUK Simply Natural Freemie Mobile Pump

Basic Pump Operation

Covers turning the pump on/off, initial settings, and notes on charging and battery life.

Adjusting Suction, Speed, and Timer

Guidance on adjusting suction levels, speed cycles, using Turbo mode, and setting the auto shut-off timer.

Memory Settings and Usage Adjustment

Instructions for programming memory buttons and advice on adjusting to hands-free pumping.

Stopping the Pump Safely

Methods to stop the pump, including breaking suction, and advice for pain during pumping.

Disconnecting and Transferring Milk

Steps for Post-Pumping Disconnection

Procedure for turning off the pump, disconnecting tubing, and removing cups from the bra.

Handling Full Collection Cups

Information on cup capacity, emptying full cups, and minimizing pumping interruptions.

Pain During Pumping

Advice on stopping pumping and consulting a professional if pain is experienced.

Pouring Milk into a Container

Using the Pour Spout

Guidance on using the pour spout for safe and spill-free milk transfer into storage containers.

Immediate Post-Transfer Cleaning

Reminder to disassemble and clean parts immediately after transferring milk for next use.

Proper Storage of Breast Milk

Breast Milk Storage Guidelines

A chart detailing recommended storage durations and temperatures for breast milk in various locations.

Optimal Storage Location Tips

Advice on storing milk in refrigerators and freezers for maximum freshness and quality.

Thawing and Using Stored Breast Milk

Safe Thawing Methods

Instructions for thawing frozen milk using refrigerator or running water, and heating.

Milk Heating and Testing Precautions

Guidance on warming milk safely and testing temperature before feeding to prevent burns.

Post-Thaw Milk Storage

Rules for storing thawed milk, including limits on refrigeration time and refreezing.

Troubleshooting: Breasts Not Emptying

Nipple Alignment and Bra Fit

Advice on centering the nipple in the funnel and adjusting bra fit for effective milk release.

Funnel Size and Position Adjustment

Tips on adjusting cup position and consulting for funnel size if emptying problems persist.

Troubleshooting Common Issues

Addressing Loss of Suction

Steps to diagnose and fix issues causing reduced suction, like improper assembly or kinks.

Preventing Milk in Tubing

Guidance on ensuring proper assembly and barrier integrity to avoid milk entering the tubing.

Warranty & Specifications

Product Warranty and Warnings

Details warranty periods for pump mechanism and parts, and usage warnings.

Disposal and Recycling Guidelines

Instructions on how to properly dispose of the pump and power adapter as electronic waste.

Technical Product Specifications

Lists key specifications including medical device classification, power input/output, battery, and protection class.

EMC Guidance and Symbols

Electromagnetic Compatibility Warnings

Advisories on operating the pump near other electronic devices that emit electromagnetic waves.

FCC Part 15 Compliance Statement

Information regarding the device's compliance with FCC rules for digital devices.

Pump Motor Unit Symbols Explained

Descriptions of symbols found on the pump, such as disposal and operating instructions references.

Spare Parts & Customer Service

Available Spare Parts List

A list of available spare parts with corresponding part numbers for ordering.

Customer Support Contact Information

Provides customer service phone number and operating hours for assistance.

Related product manuals