Numatics G3 Series EtherNet/IP Specifications

General IconGeneral
BrandNumatics
ModelG3 Series EtherNet/IP
CategoryI/O Systems
LanguageEnglish

Summary

G3 Series Introduction

Communication Module

Power Consumption

External Fuse Sizing Chart

Provides guidance for selecting external fuse sizes based on power consumption.

Diagnostics

Communication Module LED Functions

Explains the status indications provided by the module's LEDs.

Output Short Circuit Protection

Details the status bit actions during fault conditions for outputs.

G3 Graphic Display

Graphic Display Configuration

Setting the IP Address via Graphic Display

Step-by-step instructions for setting the IP address using the graphic display.

Setting the Subnet Mask via Graphic Display

Step-by-step instructions for setting the subnet mask using the graphic display.

Configuring DHCP/BOOTP via Graphic Display

Instructions for enabling or disabling DHCP/BOOTP via the graphic display.

Advanced Settings

Fault Action Settings

Configures the output action during a fault state (OFF, Hold Last State).

Idle Action Settings

Configures the output action during an idle state (OFF, Hold Last State).

Factory Defaults

Restoring Factory Default Settings

Procedure to reset all parameters to factory default conditions.

Diagnostics Operations

Self Test Mode Operation

Enables and guides users through the self-test mode for I/O and manifold functionality.

Error Messages

Manual Configuration Module (MCM)

DIP Switch Settings

IP Address Configuration via DIP Switches

Explains manual IP address setup using DIP switches.

Auto Recovery Module (ARM)

Digital I/O Modules

Analog I/O Modules

EtherNet/IP™ Configuration and Mapping

Connecting to a G3 Series Node

Establishing a Network Connection

Steps to connect a computer to the G3 EtherNet/IP node via network.

Configuring Computer's Local Area Connection

Details how to configure the computer's network settings for connection.

Setting Computer's IP Address

Instructions for setting the computer's IP address and subnet mask.

Web Server Functionality

Node Configuration via Web Server

Configuring node parameters like IP, Subnet, and communication modes.

I/O Force and Test Functions

Testing outputs and monitoring inputs through the web interface.

Monitoring Diagnostics via Web Server

Viewing MAC Address, Serial Number, and Valve Diagnostics Table.

IP Address Configuration Methods

DHCP/BOOTP Configuration

Using DHCP/BOOTP servers for automatic IP address assignment.

Integrated Web Page Configuration

Configuring IP address and other parameters via the node's web server.

Manual Configuration via DIP Switch

Setting IP address manually using DIP switches.

Configuration with RSLogix 5000

Setting Connection Parameters in RSLogix 5000

Entering specific values in RSLogix 5000 for manifold configuration.

User Configurable Parameters

Communication Fault/Idle Mode

Communication Fault/Idle Mode Parameter

Defines output behavior during communication faults or idle states.

EtherNet/IP™ Mapping

Bit Mapping Rules

I/O Mapping Examples

Factory Default Settings

Default Parameter Values

Lists default values for IP address, Baud Rate, DHCP/BOOTP, etc.

Troubleshooting

Communication Node Troubleshooting

Addresses common issues with the communication node and their solutions.

I/O Module Troubleshooting

Addresses common issues with I/O modules and their solutions.

Technical Support

Contacting Numatics for Support