79
Ethernet: 100GBASE-CR4, 100GBASE-KR4, 100GBASE-SR4, 50GBASE-R2, 50GBASE-
R4, 40GBASE-CR4, 40GBASE-KR4, 40GBASE-SR4, 40GBASE-LR4, 40GBASE-ER4,
40GBASE-R2, 25GBASE-R, 20GBASE-KR2, 10GBASE-LR,10GBASE-ER, 10GBASE-
CX4, 10GBASE-CR, 10GBASE-KR, SGMII, 1000BASE-CX, 1000BASE-KX, 10GBASE-SR
Data Rate InfiniBand SDR/DDR/QDR/FDR/HDR100/EDR
Ethernet 1/10/25/40/50/100 Gb/s
Gen3: SERDES @ 8.0GT/s, x16 lanes (2.0 and 1.1 compatible)
Adapter Card Power Voltage: 12V, 3.3VAUX
Power Cable
Typical Power
b
Passive Cables 27.1W
Maximum Power Please refer to ConnectX-6 VPI Power Specifications (requires
MyMellanox login credentials)
Voltage: 3.3Aux
Maximum current:100mA
Maximum power available through QSFP56 port: 5W
Active Auxiliary PCIe
Connection Card Power
Typical Power 3.0W
Maximum Power 4.0W
Environmental
Temperature
Operational 0°C to 55°C
Non-operational -40°C to 70°C
Humidity: 90% relative humidity
c
Airflow (LFM) /
Ambient
Temperature
Cable Type
Airflow Direction
Heatsink to Port Port to Heatsink
Passive Cables 600 LFM / 55°C 400 LFM / 35°C
Mellanox Active
2.7W Cables
700 LFM / 55°C 400 LFM / 35°C
Regulatory Safety: CB / cTUVus / CE
EMC: CE / FCC / VCCI / ICES / RCM / KC
RoHS: RoHS Compliant
Notes: a.The ConnectX-6 adapters supplement the IBTA auto-negotiation specification to get better bit
error rates and longer cable reaches. This supplemental feature only initiates when connected to
another Mellanox InfiniBand product.
b.Typical power for ATIS traffic load.
c. For both operational and non-operational states.