Automatic power-up once some voltage is applied to the regulator input.
Pass-through mode for regulator input voltages less than 3.6 V
Small output capacitor: 2.2 uF
Stable with aluminum, tantalum or ceramic capacitors.
36.1.3 Modes of Operation
The regulator has these power modes:
RUN—The regulating loop of the RUN regulator and the STANDBY regulator are
active, but the switch connecting the STANDBY regulator output to the external pin
is open.
STANDBY—The regulating loop of the RUN regulator is disabled and the standby
regulator is active. The switch connecting the STANDBY regulator output to the
external pin is closed.
SHUTDOWN—The module is disabled.
The regulator is enabled by default. This means that once the power supply is provided,
the module power-up sequence to RUN mode starts.
36.2 USB Voltage Regulator Module Signal Descriptions
The following table shows the external signals for the regulator.
Table 36-1. USB Voltage Regulator Module Signal Descriptions
Signal Description I/O
reg33_in Unregulated power supply I
reg33_out Regulator output voltage O
Chapter 36 USB Voltage Regulator
KL25 Sub-Family Reference Manual, Rev. 3, September 2012
Freescale Semiconductor, Inc. 653