T1040
POR & Override
CPLD Register
CPLD
cfg_xxx
switch
Figure 2-21. CPLD and DIP switch connection
The table below shows how POR configuration is done through switches.
NOTE
0 and 1 are represented by ON and OFF respectively on the
board.
NOTE
The recommended value for the switch settings for NOR flash
is below. Refer this for value of reserved switches:
SW1: 0001 0011
SW2: 1011 1011
SW3: 1110 0001
Table 2-12. POR configuration through switches
Switch Signal name Pin Name Signal meaning Setting
SW1[1:8] cfg_rcw_src[0:7] IFC_AD[8:15] Reset Configuration
word source
Detail description see
T1040 RM
SW2[1] cfg_rcw_src[8] IFC_CLE Reset Configuration
word source
Detail description see
T1040 RM
SW2[2] cfg_ifc_te IFC_TE IFC external transceiver
enable polarity select
0: IFC drives logic 1 for
TE assertion
1: IFC drives logic 0 for
TE assertion
SW2[3] cfg_pll_config_sel_b IFC_A18 Reserved Reserved
SW2[4] cfg_por_ainit IFC_A19 Reserved Reserved
Table continues on the next page...
Chapter 2 Architecture
QorIQ T1040 Reference Design Board User Guide, Rev. 0, 06/2015