45584901TH Rev.1
11-112 /
Oki Data CONFIDENTIAL
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce-
dure
08 Setting
mode
System User
interface
8538 Toner near empty
notification setting
0 0-1 SYS 0: Disabled
1: Enabled
1
08 Setting
mode
System User
interface
Scanning 8540 Date/time format in
theMetaScanXML
file
1 0-1 SYS 0:YYYY/MM/DDhh:mm:ss.mmm
1:YYYY-MMDDThh:mm:ss.mmmTZD
1
08 Setting
mode
System User
interface
8543 Switching to the low
power consumption
mode in the Sleep
mode
1 0-1 SYS 0: Not switched
1: Switched under certain conditions
1
08 Setting
mode
System User
interface
8544 Tolerance for
switchingtoSLEEP
mode
5 5-600 SYS Setstherangeoftoleranceinwhichtheequipment
returnstotheSLEEPmodeafterthesystemisstarted
during that mode.
Unit: Second
1
08 Setting
mode
System User
interface
8546 Input setting of
minus value for
image shift when
copying
0 0-1 SYS 0: Inputting a minus value is disabled.
1: Inputting a minus value is enabled.
1
08 Setting
mode
System User
interface
Paper feeding 8548 Operation of
Tray size change
when printing is
interrupted by size
mismatch
0 0-1 SYS 0: Operation of cassette size change is disabled.
1: Operation of cassette size change is enabled.
1
08 Setting
mode
System User
interface
Counter 8549 Hardware key
control when
external counter is
installed
0 0-1 SYS 0: No control
1: Mode switch key is disabled.
1
08 Setting
Mode
System Network 8585 Edit setting of e-mail
subject
1 0-1 SYS 0: Not allowed
1: Allowed
1
08 Setting
Mode
System Network 8586 Addition of date and
time to email subject
1 0-1 SYS 0: Not added
1: Added
1
08 Setting
Mode
System Network 8587 Character string of
email subject
0 0-1 SYS Switches the default character string of subject.
0: Character string at the shipment
1: Character string specified by users
1
08 Setting
Mode
System User
control
LDAPauthentication Attribute value
setting
8592 Sender address mail - SYS Sets the default attribute value of sender address.
Maximum 32 characters (ASCII).
11
08 Setting
Mode
System User
control
LDAPauthentication Attribute value
setting
8593 Sender name uid - SYS Sets the default attribute value of sender name.
Maximum 32 characters (ASCII).
11
08 Setting
Mode
System User
interface
8597 Automatic update of
private/hold print job
list
0 0-1 SYS 0: Disabled
1: Enabled
1
08 Setting
Mode
System General Outside erase 8600 Change of default
value
0 0-1 SYS 0: Disabled
1: Enabled
1