45584901TH Rev.1
11-130 /
Oki Data CONFIDENTIAL
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce-
dure
08 Setting
mode
System General 9103 Time differences Refer
to
contents
0-47 SYS 0: +12.0h 1: +11.5h 2: +11.0h 3: +10.5h 4: +10.0h
5: +9.5h 6: +9.0h 7: +8.5h 8: +8.0h 9: +7.5h
10: +7.0h 11: +6.5h 12: +6.0h 13: +5.5h 14: +5.0h
15: +4.5h 16: +4.0h 17: +3.5h 18: +3.0h 19: +2.5h
20: +2.0h 21: +1.5h 22: +1.0h 23: +0.5h 24: 0.0h
25:-0.5h 26: -1.0h 27: -1.5h 28: -2.0h 29: -2.5h
30: -3.0h 31: -3.5h 32: -4.0h 33: -4.5h 34: -5.0h
35: -5.5h 36: -6.0h 37: -6.5h 38: -7.0h 39: -7.5h
40: -8.0h 41: -8.5h 42: -9.0h 43: -9.5h 44: -10.0h
45: -10.5h 46: -11.0h 47: -11.5h
<Default value>
ODA: 40
Others: 24
1
08 Setting
mode
System User
interface
9110 Auto-clear timer
setting
3 0-10 SYS Timertoreturntheequipmenttothedefaultsettings
when the [START] button is not pressed after the function
and the mode are set
0: Not cleared
1 to 10:
Set number x 15 sec.
1
08 Setting
Mode
System User
interface
9111 Auto power save
mode timer setting
4 0,4,6-15 SYS Timer to automatically switch to the auto power save
modewhentheequipmenthasnotbeenused
0: Invalid
4: 1 min.
6: 3 min.
7: 4 min.
8: 5 min.
9: 7 min.
10: 10 min.
11: 15 min.
12: 20 min.
13: 30 min.
14: 45 min.
15: 60 min.
1
08 Setting
Mode
System User
interface
9112 Auto Shut Off timer
setting
(Sleep Mode)
21 0-21 SYS Timer to automatically switch to the auto sleep mode
whentheequipmenthasnotbeenused
0: 3 min. 1: 5 min. 2: 10 min. 3: 15 min.
4: 20 min. 5: 25 min. 6: 30 min. 7: 40 min.
8: 50 min. 9: 60 min. 10: 70 min. 11: 80 min.
12: 90 min. 13: 100 min. 14: 110 min. 15: 120 min.
16: 150 min. 17: 180 min. 18: 210 min. 19: 240 min.
20: Invalid 21: 1 min.
1
08 Setting
Mode
System User
interface
Power save 9113 Setting for turning
the screen OFF for
Auto Power Save
mode or the Auto
Shut Off mode
1 0-1 SYS 0: OFF
1: ON
1