Technical Reference Guide – Command descriptions > 177
Sets SP bar width on the basis of parameter m, setting by
parameter S (MSB valid).
For settings other than above, the value is set to 0.
Sets height (1/180 in unit) of black bar by parameter v1
and v2.
Black bar height = v1 + v2 x 256
0(00H) <= v1 <= 255(FFH)
0(00H) <= v2 <= 255(FFH)
The maximum setting value for height is 2 in. This can be
set in units of 15/180 in as follows:
S ADJUSTMENT VALUE FOR THE STANDARD
WIDTH OF SP BAR (1/360 IN UNIT)
FDH -3
FEH -2
FFH -1
00H 0 (default)
01H +1
02H +2
03H +3
SETTING RANGE SET
VALUE
(IN)
SETTING RANGE SET
VALUE
(IN)
1 <= v1.v2 <= 15 15/180 196 <= v1.v2 <= 210 210/180
16 <= v1.v2 <= 30 30/180 211 <= v1.v2 <= 225 225/180
31 <= v1.v2 <= 45 45/180 226 <= v1.v2 <= 240 240/180
46 <= v1.v2 <= 60 60/180 241 <= v1.v2 <= 255 255/180
61 <= v1.v2 <= 75 75/180 256 <= v1.v2 <= 270 270/180
76 <= v1.v2 <= 90 90/180 271 <= v1.v2 <= 285 285/180
91 <= v1.v2 <= 105 105/180 286 <= v1.v2 <= 300 300/180
106 <= v1.v2 <= 120 120/180 301 <= v1.v2 <= 315 315/180
121 <= v1.v2 <= 135 135/180 316 <= v1.v2 <= 330 330/180