2
■ NAME AND FUNCTIONS OF BUTTONS ON WIRE CONTROLLER
TIMER ON
TIMER OFF TEMP
RESET LOCK
COOL/
HEATING
MODE
FAN SPEED
M
CLOCK
OK
ECONOMICAL
SWING
ON OF BUTTON
AJUDSTMENT BUTTON
▲
ECONOMICAL button
SWING BUTTON
COOL ONLY/COOL AND
HEATING SELECTION BUTTON
LOCK BUTTON
Timer on button
Timer off button
Clock button
OK button
Reset button
Mode selection button
FAN SPEED SELECTION
AJUDSTMENT BUTTON ▼
1) M
ode selection button:
It is used to select mode, push the button one time, then the operation modes will change in turn as follows:
AUTO → COOLING → DEHUMIDIFY → HEATING → FAN
Remarks: no heating mode if wire controller is set as the cool only.
2) Timer on button:
Push th
e button to set TIMER ON, each time you push the button the time moves forward by o.5 hours. When the set time
is over 10 hours, each time you push the button the time moves forward by 1 hour. If want to cancel the TIMER ON, then
adjust the time of TIMER ON as 0.0.
3) Timer off button:
Push
the button to set TIMER OFF, each time you push the button the time moves forward by o.5 hours. When the set
time is over 10 hours, each time you push the button the time moves forward by 1 hour. If want to cancel the TIMER OFF,
then adjust the time of TIMER OFF as 0.0.
4) CLOCK button:
Normally display the clock set currently (display 12:00 for the first electrifying or resetting). When push the button for 4
seconds, the hour part on the clock display flashes every 0.5 seconds, then push button and to adjust hour; push the
button CLOCK again, the minute part flashes every 0.5 seconds, then push and button to adjust minute. When set clock
or alter clock setting, must push the confirm button to complete the setting.
5) O
K button:
The button is used at the state of CLOCK adjustment. After select the time, push the button to confirm then exit, the
current clock will display.
6) RESET button (hidden):
Use a s
mall stick with a diameter of 1mm to push the RESET button to cancel the current settings and get into the
condition of resetting.
7) O
N/OFF butto
n:
Push the
button at the condition of OFF, the OPERATION lamp lights, as the wire controller enters into ON operation,
simultaneously sends the information of operation mode set currently, temperature, fan speed, timer etc. Push the button
at the condition of ON, the OPERATION lamp extinguishes simultaneously sends the OFF. If having set TIMER ON or
TIMER OFF, the wire controller will cancel these settings before entering into OFF, close the concern indicator, and then
send the OFF information.