UNICO ART R410A
EN - 13
ENGLISH
• Drilltheholesforanchoringthewallxingbracketusingthe4holesattheendsofthebracketasindi-
catedonthedrillingtemplateasarstpossibility(g.6).
• Ifthewallisofpoorconsistency,itisadvisabletousealargernumberofxinganchors.
Thebracketoffersmultiplepossibilitiesbothinthenumberofxingsandintheirposition.
• Thegreaterweightoftheapplianceisontheright,thereforeitispreferabletoensureamoresolidxing
from this side.
Carefully check the characteristics and consistency of the wall in order to possibly choose wall
plugs specic for particular situations.
The manufacturer will not be held liable for any underestimates made in the
structural consistency of the anchor prepared by the installer.
Therefore, pay utmost attention to the foregoing operation that could cause
serious injury/damage to people/property if carried out incorrectly.
When installing models equipped with heating pump, if no condensate discharge was built into the wall
(seeparagraph2.4.2),inordertodrainthecondensateitwillbenecessarytodrillaholethroughthe
wall in the position shown on the template.
2.4.2 - Preparing the condensate discharge
• Asregardsmachineswithheatpump,acondensationdrainpipe(g.1-ref.N)(supplied)tobeinserted
inthespecicconnection(A)(g.7).
Removethecap(B)(g.7)beforeinsertingthecondensationdrainpipe.
Whenthemaxlevelisreached,asolenoidvalveensuresthecondensatewillowoutfromtheinternal
tray.
For cold-only machines, connect the condensate discharge pipe if you intend running the unit at low
outdoortemperatures(lowerthan23°C).
Since condensate drains by gravity, there must be a minimum slope of at least 3% at every point of the
dischargeline.Usearigidorexibletubehavinganinsidediameterofatleast16mm.
If the line empties into a sewerage system, install a siphon before the point in which the pipe reaches
themaindischarge,atleast300mmbelowtheinletfromtheunit(g.8).
• Ifthedrainpipedrainsintoavessel(tankorothercontainer),thiscontainershouldnotbesealedand
thedrainpipeshouldnotremainimmersedinthewater(seeg.9).
• Theholethroughwhichthecondensatepipepassesshouldalwaysslopetowardstheoutside(seeg.
10).
The exact position in which to place the pipe inlet, as compared to the machine, is shown on the drilling
template.
Make sure, in this case, that the water expelled outward does not damage or
disturb persons or property.
During the winter this type of drainage may cause sheets of ice to form.