EN - 14
ENGLISH
When the condensate drainage is tted, pay much attention not to compress
the rubber hose.
In the event of operation during the winter with temperatures equal to or lower than 0° C, make
sure that the condensate drain pipe is protected from freezing in order to ensure draining.
In the event of prolonged operation during the winter with temperatures below 5°C, install the
optional basin heater kit.
2.4.3 - Assembly of the air ducts and external grids
• Afterdrillingtheholes(withthecoredrill),inserttheplasticsheet(H)suppliedwiththeairconditioner
(g.11)insidethem.
Sincethesheet(H)wasmadefor202mmholes,youwillhavetocutoff130mmfromthelongsideof
thesheetforthe162mmholes(g.11).
The sheets must be 65 mm shorter than the length of the wall.
• Rollthesheet(H)andinsertitintothehole,payingattentiontothesplicingline,which must always
face upwards. (g.12).
Useanordinarycutterfortheforegoingoperation(g.12).
To position the external grids, proceed as follows:
a. Applytheseal(G)tothewallange(D),ensuringitlinesupwiththeouteredgeoftheangeasindicated
inthegure13.
b. Fixthetwoangesusing2pegshavingadiameterof6mmandcheckthatthetwoxingholesare
horizontal(g.14-15-16).
c. Fitthesmalleyeletofthespring,withthelongstem,onthecappin(onbothcomponents)(g.17).
d. Insertthetwocaps(withspring),onthefrontpartoftheexternalgrid,onitstwohousings,pullinguntil
itclicks(g.18)andcouplethetwochainstothelargeeyeletofthespring.
e. Using one hand, grip the two chains connected to the grid;
f. Bendtheexternalgridsback,grippingthemwithyourfreehandwheretheybend,andinsertyourngers
insidethesinglens(g.19).).
g. Insert your arm into the pipe until the grid protrudes completely outwards.
h. Reopenthegrid,beingcarefultokeepyourngersinsidethens.
i. Turnthegriduntilthensarefullyhorizontalandtilteddownwards.
l. Pullthechain,tensioningthespring,andcouplethechainringtothepinoftheinnerangethrough
whichthepipespass(g.20).
m. Use hand shears to cut off any excess chain links.
Use exclusively the supplied grids (F), or grids with like characteristics.
2.4.4 - Preparing the holes on the machine
If Ø 202 mm holes are being used, work as follows:
a. If 162 mm pipes are being used, the removal operation of part of the rear cover must not be performed.
b. Useplierstobreakthepreblankingoftherearcover(g.21-A).
c. Then, rotate the cover part to be removed back and forth with your hand until you break the remaining
preblankedpart(g.21-B).
d. Trimexcessiveinsulatingmaterialremainedinsidetheholeusinganutilityknife(g.21-B).