EN - 16
ENGLISH
It is possible to proceed with the electrical connection using a cable embedded into the wall in a position as
indicated in the installation template (recommended connection for installing the appliance is to the upper
partofthewall).
• This operation must be performed only by the installer or any similarly qual-
ied personnel and in compliance to the current national regulations.
• To prevent the risk of an electric shock it is mandatory to switch off the main
switch before performing the electrical connections or any maintenance op-
eration to the appliances.
To replace the power cord, proceed as follows:
a. Removethelowercover(interlocking)(A)(g.25).
b. Removetheuppercover(interlocking)(B)(g.25).
c. Unscrewthe6screwsthatlockthefrontcover(g.26).
d. Removethefrontcover(C)(g.27)andremovethecoveroftheelectricalbox(D)(g.27).
e. Unscrewthecableclamp(E)(g.27)andunscrewthecablelockingscrewsoftheterminalblock(F)
(g.27).
f. Remove the present cable and insert the new cable following the same path.
g. Remove the wooden wedge on the back of the machine.
h. Lockthethreepolesofthecableintheterminalblockandtightenthescrews(F)(g.27).
i. Securethecablewiththeclamp(E)(g.27).
l. Closetheboardprotection(D)(g.27).
m. Retthefrontcoverofthemachinewiththesixscrews.
n. Reassemblethetwointerlockingcovers(upperandlower).
These operations must be carried out with the machine already positioned on the bracket, also
carefully read the following instructions before completing the electrical connection.
2.5 - TOP/BOTTOM INSTALLATION CONFIGURATION
Theunitcanbeinstalledbothinthelowerpart(adjacenttotheoor)andintheupperpart(adjacenttothe
ceiling)ofthewall.
Tooptimizeairdistributionandambientcomfort,thedirectionoftheairowcanbechangedbychanging
thepositionoftheairoutletap.
AIR OUTLET FLAP CONFIGURATION CHANGE FROM LOW WALL TO HIGH WALL AND VICE VERSA
Workasfollows(seeg.28-29):
a. Delicatelyopentheapanddetachitfromitssideandcentralhooksonthedeectors.
b. Removethepin(P1)androtatetheap180°.
c. Insertthepin(P1)ontherightsideoftheap.
d. Re-inserttheapbyinsertingthepin(P1)inthelowerholelocatedontherightoftheopening(P2)and
insert the pin already located in the appliance in the lower hole located on the left of the opening.
UPPER WALL CONFIGURATION DETERMINES AN AUTOMATIC CORRECTION OF THE ROOM
TEMPERATURE EQUAL TO 3°C IN HEATING MODE.
For correct functionality, each modication of the conguration of the air outlet
ap must correspond to the relative modication of the electronic conguration.