EN - 32
ENGLISH
Malfunctioning Cause What must be done?
The unit will not start. Current failure Wait for the current to be restored.
The unit is disconnected from the
current.
Check that the plug is inserted in the
wall socket.
The fuse is interrupted or the ther-
mal-magnetic circuit breaker has
tripped.
Replace the fuse or restore the ther-
mal-magnetic circuit breaker.
The remote control batteries may be
discharged.
Replace the batteries.
The time set with the timer may not
be correct.
Wait or annul the timer setting.
The appliance doesn’t cool/heat
sufcientlyanymore.
Incorrect temperature setting. Set the temperature correctly. Consul
the "Using the remote control" chapter
for the procedure.
Theairlterisdirty. Cleantheairlter.
The doors or windows are open. Close the doors or windows.
The air inlet or outlet vents of the
indoor or outdoor units are blocked.
First, remove the obstructions and
then re-start the unit.
If the problem has not been solved, please contact the nearest technical assistance service.
Please give detailed information about the malfunction and on the equipment version.
4.3.5 - Anomalies and remedies
5 - TECHNICAL DATA
For the technical data listed below, consult the characteristic data plate afxed to the product.
• Power supply voltage
• Maximum power absorbed
• Maximum current absorbed
• Cooling capacity
• Refrigerant gas
• Protection rating of the casings
• Max. operating pressure
• Hermetically sealed appliance.
ContainsuorinatedgreenhousegasR410A
• Dimensions(WidthxHeightxDepth) ..........................mm 902 x 508 x 231
• Weight(withoutpackaging) ..........................................kg 39
OPERATING LIMIT
CONDITIONS
INDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
Maximum operating temperatures in
cooling mode
DB 35°C - WB 24°C DB 43°C - WB 32°C
Minimum operating temperatures in
cooling mode
DB 18°C DB -10°C
Maximum operating temperatures in
heating mode
DB 27°C DB 24°C - WB 18°C
Minimum operating temperatures in
heating mode
- - - DB -15°C