2.2 - CHOOSING THE POSITION OF THE UNIT
To obtain the best operating performance and prevent faults or hazardous conditions, the position of indoor
unit installation must meet the following requirements:
a. Donotexposetheappliancetoheatorsteamsources(g.3).
b. Make sure that the space to the right and left is at least 60 mm and space above the unit is at least 80
mm.(g.2).
c. Theheightoftheunit’sloweredgefromtheoorshouldbeatleast100mmifxedtothewallinthe
lowestposition.Ifxedtothewallinthehighestposition,itshouldbeatleast80mmfromtheceiling
(g.2).
d. UNICOWALLcannotbeinstalledataheightlowerthan2metersfromtheoor.
Thewallwheretheindoorunitistobexed,mustbestable,strongandsuitabletosupporttheweight.
e. It must be possible to leave room around the unit for any maintenance operations that may be necessary.
f. Nothing should be in the way of the air that needs to circulate both on the top air-intake (curtains, plants,
furniture) and at the front where the air exits. This could cause air swirls that would inhibit the working
efciencyoftheunit(g.3).
g. Donotspraywaterorotherliquidsofanykinddirectlyontheunit(g.3).
h. Theappliancemustnotbepositionedsothattheairowisdirecteddirectlytowardsnearbypeople(g.
3).
i. Neverforcetheopeningoftheairowap(g.3).
l. Donotplacebottles,cans,clothes,owersoranyotherobjectontheairsuctiongrille(g.3).
m. Do not install the air conditioner directly on another household appliance (TV, radio, fridge, etc.), or on
aheatsource(g.3).
The air conditioner must be installed on a wall that communicates with the outside
After determining the best place for installation as described above, check for
the absence of other structures or systems (beams, piers, pipes, wires, etc.) at
the points where the holes are to be drilled, which would prevent drilling the
holes required to install the unit.
Check again to make sure there are no obstacles to air circulation through the
holes to be drilled due to plants and their leaves, slats or panelling, blinds, grat-
ings or grids too dense, etc.).
2.3 - INSTRUCTIONS FOR INSTALLATION UNICO MASTER
To obtain the best results and optimum performance, follow the instructions for correct installation provided
in this manual.
A failure to implement the indicated standards, which may cause a malfunction
of the appliances, relieves OLIMPIA SPLENDID from any form of warranty and
from any liability for possible damages caused to people, animals or things.
The electrical system must be compliant with legal standards, must respect
the data in the technical data sheet and be must be equipped with an efcient
ground system.