ENGLISH
EN - 14
2.3.1.3 - ASSEMBLY OF THE AIR DUCTS AND EXTERNAL GRIDS
• Afterdrillingtheholes(withthecoredrill),inserttheplasticsheet(G)suppliedwiththeairconditioner
(g.11)insidethem.
Since the sheet (G) was made for 202 mm holes, you will have to cut off 130 mm from the long side of
thesheetforthe162mmholes(g.11).
The sheets must be 65 mm shorter than the length of the wall.
• Rollthesheet(G)andinsertitintothehole,payingattentiontothesplicingline,which must always
face upwards. (g.12).
Useanordinarycutterfortheforegoingoperation(g.12).
To position the external grids, proceed as follows:
a. Applytheseal(F)tothewallange(D),ensuringitlinesupwiththeouteredgeoftheangeasindicated
inthegure13.
b. Fixthetwoangesusing2pegshavingadiameterof6mmandcheckthatthetwoxingholesare
horizontal(g.14-15-16).
c. Fitthesmalleyeletofthespring,withthelongstem,onthecappin(onbothcomponents)(g.17).
d. Insert the two caps (with spring), on the front part of the external grid, on its two housings, pulling until
itclicks(g.18)andcouplethetwochainstothelargeeyeletofthespring.
e. Using one hand, grip the two chains connected to the grid;
f. Bendtheexternalgridsback,grippingthemwithyourfreehandwheretheybend,andinsertyourngers
insidethesinglens(g.19).).
g. Insert your arm into the pipe until the grid protrudes completely outwards.
h. Reopenthegrid,beingcarefultokeepyourngersinsidethens.
i. Turnthegriduntilthensarefullyhorizontalandtilteddownwards.
l. Pullthechain,tensioningthespring,andcouplethechainringtothepinoftheinnerangethrough
whichthepipespass(g.20).
m. Use hand shears to cut off any excess chain links.
Use exclusively the supplied grids (E), or grids with like characteristics.
2.3.1.4 - PREPARING THE HOLES ON THE MACHINE
The unit was built to be paired with 162-mm pipes and, in order to obtain best performance and noiseless-
ness,youshouldusethe202-mmholes.Conguretheunitasfollows:
• Useacuttertopunchanopeningontherearcoverandremovethecoveringpart(g.21)soastocreate
the air passage hole having a diameter of 202 mm.
2.3.1.5 - POSITIONING THE APPLIANCE
• Toxthebracket,drilltheholesonthewallinthechosenpositionandxitwiththesupplieddowels
(g.22).
• Correctlypositionthebracketbymeansofalevelandtightentheplateusingthecorrespondingscrews
(g.22).
Work as follows:
a. Raisetheairconditionerholdingitbythesidesofthelowerbaseandhookittotheplate(L1)(g.24).
Slightly tilt the lower part of the appliance towards yourself to ease the operation.