10. Service Mode Field Service Ver. 1.0 Jun. 2008
198
Adjustment / Setting
Mode Default value
350
Bit 7654 3210
HEX: 28
State 0010 1000
Bit Setting item
Setting value
Description
01
6 POP3 before SMTP
No Yes
5-4 Maximum width of document to be transmit-
ted when the fax capability of the receiver is
set to [Advanced]
(Network function)
00 A4 Default
value of
maximum
width of
document to
be transmit-
ted
01 B4
10 A3
11
Not avail-
able
3-2 Maximum resolution to be used when the fax
capability of the receiver is set to [Advanced]
(Network function)
00
200 x 200
dpi
Default
value of
maximum
resolution to
be used
01
400 x 400
dpi
10
600 x 600
dpi
11
Not avail-
able
Mode Default value
351
Bit 7654 3210
HEX: 1C
State 0001 1100
Bit Setting item
Setting value
Description
01
7 Gateway transmission (Network function)
Not
allowed
Allowed
Specify allowed or not
allowed for sending e-mail
using gateway communi-
cations.
If “Not allowed”, SMTP
reception is executed,
however gateway trans-
mission is not executed,
and received data is
printed.
6-5 Outgoing port for gateway transmission (Net-
work function)
Specify an outgoing port for fax transfer (fax
transfer of received e-mail file) through gate-
way transmission.
(valid for G3 multi-port only) [See note.]
00 G3-1
11 G3-2
others Not available
3Gateway TSI
Normally
not add
Normally
add
d-Color MF201
Service Manual Y109660-1
d-Color MF201