IMPACT ECHO (IE)
www.olsoninstruments.com www.olsonengineering.com
An indication of internal cracks is the multiple peak character in the frequency domain with the dominant
peak representing shallower than the expected thickness. The picture below shows the data with internal
cracks detected at approximately 6.5” measured from the test surface.
Related Peer Reviewed Papers
Calculated Echo Depth = 6.5Calculated Echo Depth = 6.5”