Error “Lt” is shown on
controller
*controller
* sensor
● Lt error occurs when dew point temperature value drops below -2°C
● Bypass valve is not set properly unscrew the protection cap and
tighten the nub in a counter clockwise fashion for 1 full turn (360°),
wait if dew point values are raising, if not repeat process
● May occur if the ambient temperature is to low
Error “Cln” is shown on
controller
*controller
* sensor
● Cln error occurs when the temperature on the condenser surpasses
70°C
● May occur if the ambient temperature is too high
May occur if condenser coil is dirty please clean the condenser coil.
May occur if the fan is not working (there is no ambient airflow
through the dryer) - please check the electrical wiring of the fan.
May occur if there is a bad connection of temperature sensor Ntc.
Cond. to the controller check if the connection of condenser
temperature sensor is good.
Error ”Ht” is shown on
controller
*controller
*sensor
● Ht error occurs when the temperature of compressor surpasses
110°C
Check the copper tubing for any leakage there may very well be a
leakage and the temperature goes above 110°C due to insufficient
coolant in the system
High dew point
temperature shown on
controller (E.g. >5°C)
*controller
*sensor
*bypass
*copper tubing
● Check if sensor is installed correctly (placed in the insulated tubing on
evaporator inlet) adjust the placement of sensor if needed
● Bypass valve is not set properly unscrew the protection cap and
tighten the nub in a clockwise fashion for 1 full turn (360°), wait if dew
point values are lowering, if not repeat process
● There could be a leakage of coolant in the system – of possible check
the pressure of the dryer on service valves
● May occur if the ambient temperature is too high
Fan on condenser does
not work
*fan
*controller
● Check the electrical wiring of the fan
● Check the output voltage for fan on the controller
● Check the working of the fan itself (connect it to an external power
supply)
Dryer does not start
*controller
*sensor
*bypass
*copper tubing
● Check the electrical installation (internal and external).
● Check if the controller is malfunctioning (E.g. is there output voltage
on the controller pins after start up time has elapsed)
● Check if there are not safety switches (high and low pressure) active
(this applies for first dryer start after it has been installed)
● If the dryer is 3 phase powered, check if the phase sequence is
correct
● There could be leakage of coolant in the system of possible check
the pressure of the dryer on service valves
* part/category with issue
NOTE: When the condensate drain is in alarm condition, the solenoid valve will open every 7
minutes for 7.5 seconds