1973
Cal. 1310
21
5.1 Measuring of the rate (Deltatest)
Press key (2) of keyboard " < 15' Hz" ["1 Hz ".]
Move the watch in order to secure maximum 
signal.
Regulate amplification (6) by observing the level 
control provided by the instrument hand (7). 
Optimal adjustment is secured when the hand is at 
the beginning of the black zone [green zone]
Select by means of (3) the measuring time of 12 
[10] seconds.
Select by means of (4) the measuring accuracy of 
.99 [1/100.]
6.1 Measuring of the power cell tension (Alitest)
With power cell placed on table, connect black 
probe to top of power cell (-) and red probe to its 
case (+).
The tension value must be in the region of 1.35V; 
if it is below 1.25V, the power cell must be 
replaced.
6.2 Measuring of the current (Alitest)
This measuring is effected by using substitute 
power cell feed (15) connected with "Output" by 
means of the feeding clip (13).
Press buttons (2) [1.35 V] relating to feed tension 
of the watch and (8) [µA] enabling the current to 
be measured.
The value measured should not exceed 15 µA.
6.3 Checking of the functioning limit tensions 
(Alitest)
This checking is effected by using substitute 
power cell feed (15) connected with "Output" by 
means of the feeding cable (13).
Press buttons (4) [Uadj] and (9) [Vadj].
Check proper functioning of movement within the 
tension limits of 1.15 V and 1.40 V (tensions are 
regulated by means of knob (5)).
Note
The motor is said to function normally when the 
second wheel makes one complete revolution in 
one minute. It is important to check the passage of 
each of the 60 teeth.
6.4 Analysis of motor - measuring of the coil 
resistance
Note:
If the movement is under tension, it is necessary to 
isolate the electronic module before measuring the 
resistance.
Unscrew the two motor connecting-screws.
Slide an insulating leaf under the terminals of the 
module (A and B).
Measure R by applying the probes (16) to the 
terminals A and B.
The resistance of the motor
should be between 2 and 2.2 K. If this is not the 
case, the motor module must be changed.
6.5 Measuring of the rate on Deltatest using 
feed from Alitest
Connect Alitest to "Input"
of Deltatest by means of the special cable.
Proceed in identical manner to 6.2 : Measuring of 
the current.
Press button Atten. Deltatest (12) [Switch on back 
of Alitest in position 1].