Personal Daq User’s Manual Appendix B, 887095 API Commands B-33
Table 9. API Error Codes
Error Name
Code #
hex - dec
Description
DerrNoError 00h - 0
No error
DerrBadChannel 01h - 1
Specified LPT channel was out-of-range
DerrNotOnLine 02h - 2
Requested device is not online
DerrNodaqbook 03h - 3
daqBook is not on the requested channel
DerrBadAddress 04h - 4
Bad function address
DerrFIFOFull 05h - 5
FIFO Full detected, possible data corruption
DerrBadDma 06h - 6
Bad or illegal DMA channel or mode specified for device
DerrBadInterrupt 07h - 7
Bad or illegal INTERRUPT level specified for device
DerrDmaBusy 08h - 8
DMA is currently being used
DerrInvChan 10h - 16
Invalid analog input channel
DerrInvCount 11h - 17
Invalid count parameter
DerrInvTrigSource 12h - 18
Invalid trigger source parameter
DerrInvLevel 13h - 19
Invalid trigger level parameter
DerrInvGain 14h - 20
Invalid channel gain parameter
DerrInvDacVal 15h - 21
Invalid DAC output parameter
DerrInvExpCard 16h - 22
Invalid expansion card parameter
DerrInvPort 17h - 23
Invalid port parameter
DerrInvChip 18h - 24
Invalid chip parameter
DerrInvDigVal 19h - 25
Invalid digital output parameter
DerrInvBitNum 1Ah - 26
Invalid bit number parameter
DerrInvClock 1Bh - 27
Invalid clock parameter
DerrInvTod 1Ch - 28
Invalid time-of-day parameter
DerrInvCtrNum 1Dh - 29
Invalid counter number
DerrInvCntSource 1Eh - 30
Invalid counter source parameter
DerrInvCtrCmd 1Fh - 31
Invalid counter command parameter
DerrInvGateCtrl 20h - 32
Invalid gate control parameter
DerrInvOutputCtrl 21h - 33
Invalid output control parameter
DerrInvInterval 22h - 34
Invalid interval parameter
DerrTypeConflict 23h - 35
An integer was passed to a function requiring a character
DerrMultBackXfer 24h - 36
A second background transfer was requested
DerrInvDiv 25h - 37
Invalid Fout divisor
Temperature Conversion Errors
DerrTCE_TYPE 26h - 38
TC type out-of-range
DerrTCE_TRANGE 27h - 39
Temperature out-of-CJC-range
DerrTCE_VRANGE 28h - 40
Voltage out-of-TC-range
DerrTCE_PARAM 29h - 41
Unspecified parameter value error
DerrTCE_NOSETUP 2Ah - 42
dacTCConvert called before dacTCSetup
daqBook
DerrNotCapable 2Bh - 43
Device is incapable of function
Background
DerrOverrun 2Ch - 44
A buffer overrun occurred
Zero and Cal Conversion Errors
DerrZCInvParam 2Dh - 45
Unspecified parameter value error
DerrZCNoSetup 2Eh - 46
dac…Convert called before dac…Setup
DerrInvCalFile 2Fh - 47
Cannot open the specified cal file
Environmental Errors
DerrMemLock 30h - 48
Cannot lock allocated memory from operating system
DerrMemHandle 31h - 49
Cannot get a memory handle from operating system
Pre-trigger acquisition Errors
DerrNoPreTActive 32h - 50
No pre-trigger configured