Setting/Releasing Cam Protect Procedure 1 (Enabling Cam Protect Settings)
Cam protect (bank number 1) Cam protect (bank number 1, cam number 1) Cam protect (bank number 1, cam number 32)
Use the mode selection switch to change to SET mode.
Cam protect
Up to cam number 16 for 3F88L-160.
Cam protect (bank number 2) Cam protect (bank number 2, cam number 1) Cam protect (bank number 2, cam number 32)
Up to cam number 16 for
3F88L-160.
Cam protect (bank number 8) Cam protect (bank number 8, cam number 1) Cam protect (bank number 8, cam number 32)
Up to cam number 16 for 3F88L-160.
Up to bank number 4 for 720 resolution.
Bank number
selection possible
Cam protect settings
possible
S Use the Bank/Function Key to set cam protect (Function No. C) and press the Set Key, and the
bank number will flash in the Bank/Function display (indicating that bank number selection is en-
abled.)
Use the Up and Down Keys to set the bank number containing the cam to be cam protected.
S Next, press the Set Key to display the cam number in the Cam/Parameter No. display. The current
cam protect status will be displayed in the SPEED/ON and POSITION/OFF displays (and cam
protect settings can be made).