EasyManua.ls Logo

Omron 3F88L-160 - Page 137

Omron 3F88L-160
238 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function level 2
3-81
Note 3. Cam programs created using the pulse output function, like other cam programs, can be
edited and deleted in PRGM mode and edited freely using compensation and trial operations.
Note 4. The pulse output function creates cam programs and does not store the parameters set here
in memory.
Note 5. Refer to 3-5-3 Cam Program Creating and Checking for information on how to check cam pro-
grams that have been created using this function.
Note 6. If the pulse output function is used to create a new cam program for a cam number that al-
ready has a cam program input, the existing cam program does not have to be cleared before-
hand. When pulse output settings are made, all existing cam programs are cleared and over-
written by the pulse output cam program.
H Operation Example
w For Pulse Number = 4, Pulse Start Position = 30°
Cam output (cam program)
H Related Parameters (SET Mode)
D Pulse Output Setting
Function
No.
P (p)
Parameter
No.
--- Setting range ---
Use this parameter to create pulse output programs.
Operation Chapter 3

Table of Contents