3-82
Operation
Pulse output (bank number 1) Pulse output (bank number 1, cam number 1)
Pulse output (bank number 1, cam number 32)
Use the mode selection switch to change to SET mode.
Pulse output setting
Up to cam number 16 for 3F88L-160.
Pulse output (bank number 2) Pulse output (bank number 2, cam number 1)
Pulse output (bank number 2, cam number 32)
Up to cam number 16 for 3F88L-160.
Pulse output (bank number 8) Pulse output (bank number 8, cam number 1) Pulse output (bank number 8, cam number 32)
Up to cam number 16 for 3F88L-160.Up to bank number 4 for
720 resolution
Pulse number
selection enabled
Pulse output setting
enabled
• Use the Bank/Function Key to make the pulse output settings (Function No. P) and press the Set Key
and the bank number will flash in the Bank/Function display. Use the Up and Down Keys to set the
bank number that contains the cam for which a pulse output program is to be created.
• Next, press the Set Key to display the cam number in the Cam/Parameter No. display. Alternatively,
“P– – –” (first digit flashing) will appear in the SPEED/ON display and “– – –” will appear in the POSI-
TION/OFF display.
• Press the Cam/Parameter Key until the cam number to be set appears.
• The data that appears in the SPEED/ON display is the pulse number. Set a pulse number between 1
and 180 for 360 resolution or between 1 and 360 for 720 resolution.
• The data that appears in the POSITION/OFF display is the pulse start position. Set a pulse start posi-
tion between 0 and 359 (for 360 resolution) and 0 and 719 (for 720 resolution).
• Use the Forward, Up, and Down Keys to set the data. Use the ON/OFF Switching Key to switch be-
tween pulse number and pulse start position data.
Operation Chapter 3