5-12
5-4 Inspection and Maintenance
H Regular Inspections
There are no parts that need to be constantly maintained for the Cam Positioner equipment operation
but the following items should be checked during regular inspections to maintain performance.
• Check that the connectors are firmly connected.
• Check that there is no excessive strain on or any damage to the cables.
• Check that the Resolver rotates smoothly. Check that the axle is not displaced.
• Check that there is no excessive force on the couplings. Check that they are securely fastened.
• Check that the screws for all the terminals on the Unit are securely fastened.
H Replacement Couplings
If a Coupling has been lost, purchase the following replacement items.
Product name Model
Coupling for 3F88L-RS17 Resolver 3F88L-RL10
Coupling for 3F88L-RS15 Resolver 3F88L-RL6
Operation Chapter 5