2-8
D 3F88L-RS15W
16
max.
350 max.
43 dia.
39 dia.
16.5±0.5
33.32+0/–0.05
6–0.004/–0.016 dia.
2-2-2 Installation Environment
Take precautions with the installation environment to improve the reliability and to fully
utilize the functions of the Cam Positioner system.
H Do not install the Unit in the following locations.
Locations subject to direct sunlight.
Locations subject to ambient temperatures or relative humidities outside the following ranges.
Ambient temperature: 0° to 55°C (Cam Positioner Unit) and –10° to 80°C (Resolver)
Ambient humidity: 10 to 90 % (with no condensation).
Locations subject to condensation as the result of severe changes in temperature.
Locations subject to corrosive or flammable gases.
Locations subject to dust (especially iron dust) or salts.
Locations subject to exposure to water, oil, or chemicals.
Locations subject to shock or vibration.
H Take appropriate and sufficient countermeasures when installing the
Unit in the following locations.
Locations subject to static electricity or other forms of noise.
Locations subject to strong electromagnetic fields and magnetic fields.
Locations subject to possible exposure to radioactivity.
Locations close to power supplies.