2-17
D Terminal Functions
Terminal name Symbol Function Recommended
connection wire
diameter
Main circuit power supply
input terminal
AC1/L
Inputs the AC power supply for the Cam
Positioner. Provide a 100 to 240 V AC
1.25 mm
2
AC2/N
Positioner. Provide a 100 to 240 V AC
50/60 Hz power supply. (Rated power
supply voltage 85 to 264 V AC)
Function earth terminal This is the primary ground terminal
connected for the power supply.
2.0 mm
2
Protect earth terminal This is the frame ground terminal. 2.0 mm
2
Note 1. Use M3.5 round crimp terminals for AC 1/L and AC 2/N terminals.
Note 2. Use M3.5 round or forked crimp terminals for function earth and protect earth terminals.
7 mm max.
w Round crimp terminal w Forked crimp terminal
7 mm max.
Note If the power supply voltage of the Cam Positioner slowly increases or decreases at less than 85%
of the rated voltage (i.e., less than 85 V), operation may stop intermittently. If this affects the op-
eration of equipment, provide protective circuits that interrupt output enough to cause the voltage
to increase to more than 85% of the rated value.
H Control Input Wiring
D Wiring Method
24 V DC
Terminal screw size: M3
Tightening torque: 0.5 N S m
Design Chapter 2