2-22
D Resolver Cable Models
Resolver Extension Cables (for 3F88L-RS17/-RS17T)
2 m 3F88L-CR002C
5 m 3F88L-CR005C
10 m 3F88L-CR010C
20 m 3F88L-CR020C
50 m 3F88L-CR050C
Note 1. A maximum of two extension cables can be joined together.
Note 2. Refer to 6-2 Resolver Specifications for information on cable wire colors and pin positions.
Resolver Cables (for 3F88L-RS15)
3 m 3F88L-CR003NA
5 m 3F88L-CR005NA
10 m 3F88L-CR010NA
15 m 3F88L-CR015NA
20 m 3F88L-CR020NA
Resolver Cables (for 3F88L-RS15W)
3 m 3F88L-CR003SA
5 m 3F88L-CR005SA
10 m 3F88L-CR010SA
2-3-5 Cam Output Wiring
Cam output is an open-collector output. The wiring connectors are located on top of the
Cam Positioner Unit and the wiring is easily performed if Cam Output Cables are used.
H Cam Output Wiring Method
Use the 3F88L-CGjjjS Cam Output Cable for direct connection to PCs or Relays and the
3F88L-CGjjjN Cam Output Cable for direct connection to an I/O Block.
Note Cam output is also used for connection to Display Units. Refer to 2-3-6 Connecting a Display Unit
for details.
Cam Output Connectors
3F88L-CGjjjN
Cam Output Cable
3F88L-160/162
Cam Positioner
3F88L-CGjjjS
Cam Output Cable
G7TC-OC16
I/O Block
PC or Relay
CAM17 to 32
CAM1 to 16
Design Chapter 2