EasyManua.ls Logo

Omron 3F88L-160 - Modes, Functions, and Display

Omron 3F88L-160
238 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-4
3-2 Modes, Functions, and Display
H Modes
The 3F88L-160/162 Cam Positioner has three modes: SET, PRGM, and RUN.
Set Mode (SET)
Mode
change
Program Mode (PRGM) Operation Mode (RUN)
S Unit parameter settings
S Various compensation
value settings
S Teaching
S Communications settings
S Origin compensation
S Creation, editing, and
deletion of cam programs.
S Trial operation
S Normal operation
S Adjustment operation
S Cam output and control
I/O monitoring
S Origin shift
Mode
change
H Changing Modes
The mode selection switch is used to change modes.
Mode selection switch
H Functions by Mode
Classifi-
cation
Function name Applicable modes Conditions
Front panel
displays
Refer-
ence sec-
ca o
Function
No.
Parame-
ter No.
e ce sec
tion
Function
selection
Function level selection SET --- U 1 3-5-1
Initial
i
Resolution selection SET --- A 1 3-5-2
settings
Rotation direction
selection
SET, PRGM, RUN
Note The CW/
CCW setting
switch is
used.
--- --- --- 3-5-2
Operation Chapter 3

Table of Contents

Other manuals for Omron 3F88L-160

Related product manuals