3-24
3-5-3 Cam Program Creating and Checking (PRGM Mode/SET
Mode)
Once the initial settings have been made, turn OFF the power and then turn it ON again.
(The initial settings will be enabled once the power has been turned ON again.)
Next, create a cam program (cam output ON/OFF patterns) in PRGM mode.
Once the cam program has been created, check the number of cam program steps in
SET mode.
H Outline of Program Functions
D Cam Program Creation (PRGM Mode)
Operation Explanation
1 Set the mode selection switch to PRGM mode.
2
BANK/
FUN
Press the Bank/Function Key and set the bank number.
3
CAM/
PRMTR
Press the Cam/Parameter Key and set the cam number.
4 Set the ON angle. (Use the Up, Down, and Forward Keys)
5
ON/
OFF
Press the ON/OFF Switching Key and set the OFF angle. (Use the Up,
Down, and Forward Keys)
6
SET
Press the Set Key to confirm the settings data.
The next step can now be input. (Return to step 4 to input more steps.)
Once a program has been created for one cam number, change the cam number (using the Cam/Pa-
rameter Key) and create another cam program in the same way. If multiple bank numbers are used,
change the bank number (using the Bank/Function Key) and create another program in the same way.
D Cam Program Checking (PRGM Mode)
Operation Explanation
1 Set the mode selection switch to PRGM mode.
2
BANK/
FUN
Press the Bank/Function Key and set the bank number.
3
CAM/
PRMTR
Press the Cam/Parameter Key and set the cam number.
4 Check the ON and OFF angles.
5
SET
Press the Set Key and check the next step. (Return to step 4 of this
procedure to check the next step.)
Operation Chapter 3