3-42
D Control I/O Signal Monitor Display
w SPEED/ON (Control output) w POSITION/OFF (Control input)
3-5-8 Control I/O Signals
In addition to cam outputs (CAM 1 to 16/CAM 1 to 32), the 3F88L-160/162 Cam Position-
ers also have the control inputs and outputs described below. Refer to 2-3-3 Terminal
Block Wiring for information on wiring control I/O signals.
BANK 1 to 3
(select the bank number
to be executed)
START input
(starts cam outputs)
TRIG input
(executes origin shift)
RESET input
(hardware reset)
Cam outputs
RUN output
(enables cam outputs)
M-DET output
(outputs detection of
Resolver rotation)
ERROR output
(outputs errors)
Cam Positioner
H Control Inputs
Name Symbol Function
Bank selection
input
BANK1 Bank selection input selects which Cam Positioner bank number will be
executed. Turns ON when this signal is short-circuited with the 0V.
BANK2
Execution
bank
1 2 3 4 5 6 7 8
BANK1 OFF ON OFF ON OFF ON OFF ON
BANK2 OFF OFF ON ON OFF OFF ON ON
BANK3 OFF OFF OFF OFF ON ON ON ON
BANK3 Note Refer to 7-2 Performance for information on bank selection
timing when in operation mode.
Operation start
input
START When the operation start input is turned ON in RUN mode, the operation
will start and cam outputs are enabled.
When operation start input is turned OFF in RUN mode, cam outputs
are disabled.
Note 1. START input is ignored when the Unit is in modes other than
RUN.
Note 2. Cam outputs will turn ON and OFF during a trial operation in
PRGM mode, regardless of the START input status.
Note 3. Refer to ntl7-2 Performance for information on delay times for
cam outputs and RUN outputs after START input is turned ON.