Chapter 6
6-9
Message Communications
■ Object Details
Note 1. The default setting for the motor's rated current depends on the Inverter model. Refer to the
Inverter’s operation manual for details.
Example: 1.90A (0013 hex) for 200-V class, 0.4 kW
Note 2. The figures enclosed in parentheses in the “Setting range” and “Default” columns are the
values for 400-V class Inverters.
Note 3. The setting range for the Motor Rated Current is the setting range for the 3G3MV. With the
3G3RV/3G3PV/3G3FV, the setting range is 10% to 120% of the Inverter rated output cur-
rent.
Instance Attribute Name Content Setting range Default Read Write Size
00 01 Object Software
Revision
Indicates class 28 soft-
ware revisions. The revi-
sion value is advanced
whenever there is a
change.
--- 0001 Yes No Word
01 03 Motor Type Indicates the type of motor
to be used. The setting for
a squirrel-cage inductive
motor is 7.
--- 07 Yes No Byte
06 Motor Rated
Current
The motor's rated current
can be set and read. The
setting unit is 0.1 A. (The
setting unit can be
changed using the cur-
rent scale in Class 2A,
Instance 1, Attribute 17.)
Inverter rated
output current
10% to 150%
(See note 3.)
See note
1.
Ye s Ye s W o r d
07 Motor Rated
Voltage
The motor's rated voltage
can be set and read. The
setting unit is 1 V. (The
setting unit can be
changed using the voltage
scale in Class 2A,
Instance 1, Attribute 1B.)
0 to 255 V
(0 to 510 V)
(See note 2.)
00C8
(0190)
(See note
2.)
Ye s Ye s W o r d