Chapter 7
7-22
Configurator Settings
The combination of start signal (and command) and completion signal for operating time measure-
ment are determined as shown in the following table.
Note 1. The input references in the above table refer to the inputs in the following table. When control
I/O remote I/O is used, the input will be turned ON not only when the terminal’s signal is ON,
but also when the corresponding bit is turned ON from remote I/O. (The terminal’s ON/OFF
status is logically ORed with the status of the bit sent through remote I/O.)
Note 2. The combination of 00 and 01 is valid when combined with control I/O remote I/O and the
following parameter settings.
3G3MV: When 18 (12 hex) (communications output) is set in n057 and n058 (multi-function
outputs 1 and 2).
3G3RV/3G3PV/3G3FV: When F (not used) is set in H2-01 and H2-02 (multi-function contact
output and multi-function output 1).
Under these conditions, output from the Inverter control terminal can be controlled by com-
munications, and these signals can be used as triggers to start measurement.
Application Example
Output-to-input Example
It is possible to detect deterioration in cylinder operation and estimate expiration of the cylinder’s ser-
vice life by using the Inverter’s multi-function output to drive the cylinder and inputting the cylinder’s
travel completed signal in the multi-function input.
No. Operating time measurement trigger Remarks
Measurement start condition Measurement
completion
condition
00 Multi-function contact output: ON Input 4: ON Output to input
01 Multi-function output 1: ON Input 5: ON Output to input
02 Input 2: ON Input 3: ON Input to input
03 Input 4: ON Input 5: ON Input to input
04 Input 0 is ON, input 1 is ON, or a forward/reverse
run command is sent from the network.
Input 4: ON Forward/reverse run com-
mand to input
05 Input 0 is ON, input 1 is ON, or a forward/reverse
run command is sent from the network.
Input 5: ON Forward/reverse run com-
mand to input
Name
3G3MV 3G3RV/3G3PV 3G3FV
Input 0 Terminal S1 (multi-function
input 1) status
Terminal S1 (forward run/
stop) status
Terminal 1 (forward run/
stop) status
Input 1 Terminal S2 (multi-function
input 2) status
Terminal S2 (reverse run/
stop) status
Terminal 2 (reverse run/
stop) status
Input 2 Terminal S3 (multi-function
input 3) status
Terminal S3 (multi-function
input selection 1) status
Terminal 3 (multi-function
contact input 1) status
Input 3 Terminal S4 (multi-function
input 4) status
Terminal S4 (multi-function
input selection 2) status
Terminal 4 (multi-function
contact input 2) status
Input 4 Terminal S5 (multi-function
input 5) status
Terminal S5 (multi-function
input selection 3) status
Terminal 5 (multi-function
contact input 3) status
Input 5 Terminal S6 (multi-function
input 6) status
Terminal S6 (multi-function
input selection 4) status
Terminal 6 (multi-function
contact input 4) status