Chapter 7
7-45
Configurator Settings
3.Enter the hexadecimal value to be set in the Value field.
4.To write the parameter set values to the Inverter’s internal EEPROM (to restore the set values after
a power interruption), select the Write to EEPROM field.
5.Click the Write Button to write the set value to the Inverter.
Note When the Read Button is clicked, the set value of the specified parameter (Instance/Attribute)
is read from the Inverter and displayed as a hexadecimal in the Result field.
■ Parameter Groups and Parameters Not Set in Groups
● 3G3MV
Parameter Groups
Parameters that Cannot be Set on the Inverter Parameters Tab Page (Use the
Individual Parameters Tab)
Parameter group Details
All Parameters
Function Group 1 n002 to n049
Function Group 2 n050 to n079
Function Group 3 n080 to n119
Function Group 4 n120 to n179
Function Group 5 ENTER command (Save to EEPROM)
Function Group 6 Speed reference, speed monitor, current moni-
tor, output voltage
Parameter
No.
Class 64 Details
Instance Attribute
n001 01 01 Parameter write-prohibit selection/parameter initialization
n064 01 40 Frequency reference loss detection selection
n087 01 57 Cumulative operation time selection Can be set to 5.5 kW/7.5 kW only
n088 01 58 Cumulative operation time
n101 01 65 Speed search deceleration time
n102 01 66 Speed search level
n151 01 97 RS-422 communications settings (These parameters are not used for
DeviceNet, so they are not set.)
n152 01 98
n153 01 99
n154 01 9A
n155 01 9B
n156 01 9C
n157 01 9D
n158 01 9E Motor code (set value differs with capacity)
n166 01 A6 Open input phase detection level Can be set to 5.5 kW/7.5 kW only
n167 01 A7 Open input phase detection time
n168 01 A8 Open output phase detection level
n169 01 A9 Open output phase detection time