Chapter 7
7-58
Configurator Settings
7-4-3 IN Tab Page
Note The following table shows the meanings of the values set in the No. field
Item Reference
No. Refer to the following table for meanings in the No. field.
Note: When the present value for the maintenance counter
(cumulative ON time or contact operations count) exceeds
the monitor value, an error icon will be displayed to the left
of the corresponding No. setting (No. 05 in the above screen
example).
---
I/O Comment Displays the user-defined connected device comment for
each input terminal.
7-2-11 Connected Device
Comment
ON/OFF Displays the ON/OFF status for each input terminal. ---
Maintenance
Counter
Displays the present value of the maintenance counter for
each input terminal.
Note: Displays the cumulative ON time (in seconds) or the
contact operations count (number of times).
7-2-6 Cumulative ON Time
Monitor
7-2-7 Contact Operations
Monitor
Clear Value Button Clears the present value of the maintenance counter to
zero.
Note: Select the terminal to be cleared, and click the Clear
Button to clear the value to zero.
No. Details
3G3MV 3G3RV/3G3PV 3G3FV
00 Multi-function input 1 Forward/stop Forward/stop
01 Multi-function input 2 Reverse/stop Reverse/stop
02 Multi-function input 3 Multi-function input selection 1 Multi-function contact input 1
03 Multi-function input 4 Multi-function input selection 2 Multi-function contact input 2
04 Multi-function input 5 Multi-function input selection 3 Multi-function contact input 3
05 Multi-function input 6 Multi-function input selection 4 Multi-function contact input 4
06 Multi-function input 7 Multi-function input selection 5 Multi-function contact input 5
07
Multi-function contact input 6