Chapter 9
9-17
Communications Programs (CS-series PLCs)
Ladder Program
DIFU
(
013
)
003000
000000
000004
MOV
(
021
)
#0001
0001
MOV
(
021
)
#0010
D00100
003000
000100
000002
003000 000004
000002
MOV
(
021
)
#0010
D00100
000101
ANDW
(
034
)
D01000
#FF00
D00101
ANDW
(
034
)
D01000
#00FF
D00102
ANDW
(
034
)
0010
#00FF
D00102
ORW
(
035
)
D00101
#0002
ORW
(
035
)
#0001
D00101
D00101
MOV
(
021
)
#0003
D00100
000102
MOV
(
021
)
#0024
D00101
D00101
003002
000100
000101
000102
000103
003002
XFER
(
070
)
#0002
D00100
n
MOVD
(
083
)
D00102
#0010
n+2
000100
CMP
(
020
)
#0010
m
ANDW
(
034
)
m 1
#00FF
D01002
003100
CMP
(
020
)
#0002
D01002
003101
000300
ASL
(
025
)
0001
003100
003101
000103
MOV
(
021
)
#002C
D00101
MOV
(
021
)
#0003
D00100
000101
003103
CMP
(
020
)
#0010
m
ANDW
(
034
)
m+1
#00FF
D01002
CMP
(
020
)
#0001
D01002
003104
ANDW
(
034
)
0010
#FF00
D00101
Sets shift register.
Sets frequency reference.
Sets control input.
Reads output frequency.
Reads Inverter status.
Equals Flag (P_EQ)
Equals Flag (P_EQ)
Equals Flag (P_EQ)
Equals Flag (P_EQ)

Table of Contents