Chapter 10
10-7
Appendices
Object Details
Note 1. The setting ranges are the same as the respective remote I/O setting ranges.
Note 2. The remote I/O functions are the same as the functions explained in Chapter 5 Remote I/O
Functions.
Note 3. Remote I/O can be performed by means of message communications. When a normal re-
mote I/O communications connection is established, however, the message communica-
tions cannot be used for that purpose. Even if an attempt is made to use message
communications, they will be overwritten by remote I/O inputs.
10-2-5 DeviceNet Connection Objects: Class 05 Hex
DeviceNet connection objects are objects related to information and operations involving DeviceNet
communications connections. The Master Unit uses the information and operations of these objects
to execute the initial processing for communications.
The functions and data have no particular use for the user.
Use this object when switching the remote I/O function.
Instance Attribute Name Content Setting range Default Read Write Size
14 03 Remote I/O data Operation is the same as
for basic remote I/O (out-
put).
See note 1. 00 00 00
00
Ye s Ye s B y t e ×
4
15
03 Remote I/O data Operation is the same as
for standard remote I/O
(output).
See note 1. 00 00 00
00
Ye s Ye s B y t e ×
4
46
03 Remote I/O data Operation is the same as
for basic remote I/O
(input).
--- 00 00 00
00
Ye s N o B y t e ×
4
47
03 Remote I/O data Operation is the same as
for standard remote I/O
(input).
--- 00 00 00
00
Ye s N o B y t e ×
4
64
03 Remote I/O data Operation is the same as
for special remote I/O
(output).
See note 1. 00 00 00
00 00
Ye s Ye s B y t e ×
5
65
03 Remote I/O data Remote I/O data See note 1. 00 00 00
00 00 00
00 00
Ye s Ye s B y t e ×
8
96
03 Remote I/O data Operation is the same as
for special remote I/O
(input).
--- 00 00 00
00 00
Ye s N o B y t e ×
5
97
03 Remote I/O data Operation is the same as
for control remote I/O
(input).
--- 00 00 00
00 00 00
00 00
Ye s N o B y t e ×
8
98
03 Remote I/O data Operation is the same as
for control remote I/O +
unit status (input).
--- 00 00 00
00 00 00
00 00 00
00
Ye s N o B y t e ×
10
99
03 Remote I/O data Operation is the same as
for control remote I/O +
multi-function input moni-
tor (input).
--- 00 00 00
00 00 00
00 00 00
Ye s N o B y t e ×
9
9A
03 Remote I/O data Operation is the same as
for unit status (input).
--- 00 00 Yes No Byte ×
2
9B
03 Remote I/O data Operation is the same as
for multi-function input
monitor (input).
--- 00 Yes No Byte ×
1

Table of Contents