Appendices
Object Details
10-2-7 : Class 09 Hex
Support Service Code
Instance Attribute Name Content Setting range Default Read Write Size
00 01 Object Software
Revision
Indicates the software revision
of Class 08.
The revision value increases
when changes have been
made.
--- 0002 Yes No Word
02 Max Instance Indicates the number of input
terminals. (Depends on the
Inverter being used.)
--- 0007 Yes No Word
01 to 08
(one per
terminal)
03 Value Terminal status
00: OFF, 01: ON
--- 00 Yes No Byte
65 Lifetime mode
selection
Maintenance count method
00: Conduction time,
01: Number of ON operations
00, 01 00 Yes Yes Byte
66 Lifetime present
value
Present value of the mainte-
nance count
--- 0000
0000
Ye s Ye s
Reset
Long
67 Lifetime monitor
flag
Maintenance count compari-
son result
(ON when PV - threshold 0)
00: OFF, 01:ON
--- 00 Yes No Byte
68 Lifetime thresh-
old setting
Lifetime monitor value
Set the cumulative time that
the input is ON (s) or the num-
ber of contact operations.
0000 0000 to
FFFF FFFF
0000
0000
Yes Yes Long
Service code number (hex) Service
05 Reset (return to initial status)
0E Get attribute single
10 Set attribute single