Chapter 10
10-49
Appendices
00 86 0086 Fault output
voltage refer-
ence
Monitors U2-07; 0.1-V units
00 87 0087 Fault main cir-
cuit DC volt-
age
Monitors U2-08; 1-V units
00 88 0088 Fault output
power
Monitors U2-09; 0.1-kW units (with sign)
00 89 0089 Fault torque
reference
Monitors U2-10; 0.1% units (100% = motor's rated
torque; with sign)
00 8A 008A Fault input ter-
minal status
Monitors U2-11 (same contents as U1-10)
00 8B 008B Fault output
terminal status
Monitors U2-12 (same contents as U1-11)
00 8C 008C Fault operating
status
Monitors U2-13 (same contents as U1-12)
00 8D 008D Fault cumula-
tive operation
time
Monitors U2-14; 1-hr units
00 (08) 90 (00) 0090 (0800) Content of last
fault
Monitors U3-01 (same codes as U2-01)
00 (08) 91 (01) 0091 (0801) Content of 2nd
prior fault
Monitors U3-02 (same codes as U2-01)
00 (08) 92 (02) 0092 (0802) Content of 3rd
prior fault
Monitors U3-03 (same codes as U2-01)
00 (08) 93 (03) 0093 (0803) Content of 4th
prior fault
Monitors U3-04 (same codes as U2-01)
00 (08) 94 (0A) 0094 (080A) Cumulative
operation time
since last fault
Monitors U3-05; 1-hr units
00 (08) 95 (0B) 0095 (080B) Cumulative
operation time
since 2nd prior
fault
Monitors U3-06; 1-hr units
00 (08) 96 (0C) 0096 (080C) Cumulative
operation time
since 3rd prior
fault
Monitors U3-07; 1-hr units
00 (08) 97 (0D) 0097 (080D) Cumulative
operation time
since 4th prior
fault
Monitors U3-08; 1-hr units
08 04 0804 Connect of 5th
prior fault
Monitors U3-09 (same codes as U2-01) (See note.)
08 05 0805 Connect of 6th
prior fault
Monitors U3-10 (same codes as U2-01) (See note.)
08 06 0806 Connect of 7th
prior fault
Monitors U3-11 (same codes as U2-01) (See note.)
08 07 0807 Connect of 8th
prior fault
Monitors U3-12 (same codes as U2-01) (See note.)
Class 64 Register
number (hex)
Content
Instance Attribute