Chapter 10
10-50
Appendices
Note U3-09 to U3-20 are not supported for Asian models. Register No. 0800 Hex to 0813 Hex are
not supported for Asian models.
10-5-3 Parameter Reading and Writing
The following tables show the SYSDRIVE 3G3RV Inverter parameters and the corresponding regis-
ter numbers. Write and read the various parameters with “1" as the minimum setting unit. Negative
numbers are expressed as two's complement. If the setting unit is in hexadecimal, there is no need to
convert it.
When writing data in parameters, be sure to send an enter command to enable the written data.
Unless the enter command is transmitted, the data will not be enabled and the Inverter may not start.
08 08 0808 Connect of 9th
prior fault
Monitors U3-13 (same codes as U2-01) (See note.)
08 09 0809 Connect of
10th prior fault
Monitors U3-14 (same codes as U2-01) (See note.)
08 0E 080E Cumulative
operation time
since 5th prior
fault
Monitors U3-15; 1-hr units (See note.)
08 0F 080F Cumulative
operation time
since 6th prior
fault
Monitors U3-16; 1-hr units (See note.)
08 10 0810 Cumulative
operation time
since 7th prior
fault
Monitors U3-17; 1-hr units (See note.)
08 11 0811 Cumulative
operation time
since 8th prior
fault
Monitors U3-18; 1-hr units (See note.)
08 12 0812 Cumulative
operation time
since 9th prior
fault
Monitors U3-19; 1-hr units (See note.)
08 13 0813 Cumulative
operation time
since 10th
prior fault
Monitors U3-20; 1-hr units (See note.)
Class 64 Register
number (hex)
Content
Instance Attribute