Chapter 10
10-58
Appendices
Note 1. Values in parentheses are for 400-V-class Inverters.
Note 2. The setting range is 10% to 200% of the Inverter's rated output current. The values for a 200-
V-class 0.4-kW Inverter are given above.
Note 3. When the control mode is changed, the Inverter will revert to default settings. (The V/f control
default settings are given above.)
Note 4. E1-13 will be the same value as E1-05 after autotuning.
Note 5. The upper setting limit will be 150.0 Hz when C6-01 is set to 0.
Note 6. The settings of E1-11 and E1-12 are ignored if set to 0.0.
Note 7. If multi-function input H1-@@ is set to 16 (motor 2), the default setting will depend upon the
Inverter capacity. The value for a 200-V-class 0.4-kW Inverter is given.
Note 8. Values in parentheses are for Asian model Inverters.
Option Parameters
E4-03 0323 03 23 Motor 2 no-load current 0.00 to
1.89
(See
note 7.)
0.01 A Depends
on
capacity.
No
E4-04 0324 03 24 Motor 2 number of poles (number of
poles)
2 to 48 1 pole 4 No
E4-05 0325 03 25 Motor 2 line-to-line resistance 0.000 to
65.000
0.01 Depends
on
capacity.
No
E4-06 0326 03 26 Motor 2 leak inductance 0.0 to
40.0
0.1% Depends
on
capacity.
No
E4-07 0327 03 27 Motor 2 rated capacity 0.40 to
650.00
0.01 kW Depends
on
capacity.
No
Con-
stant
Regis-
ter num-
ber
(hex)
Class 64 (hex) Name Setting
range
Setting
unit
Default
setting
Write
during
opera-
tion
In-
stance
At-
tribute
F1-0103800380PG constant 0 to
60000
1 1024
(600)
(See
note.)
No
F1-02 0381 03 81 Operation selection at PG open circuit
(PGO)
0 to 311No
F1-03 0382 03 82 Operation selection at overspeed (OS) 0 to 3 1 1 No
F1-04 0383 03 83 Operation selection at deviation 0 to 3 1 3 No
F1-0503840384PG rotation 0, 1 1 0 No
F1-06 0385 03 85 PG division rate (PG pulse monitor) 0 to 132 1 1 No
F1-07 0386 03 86 Integral value during accel/decel
enable/disable
0, 110No
F1-08 0387 03 87 Overspeed detection level 0 to 120 1% 115 No
F1-09 0388 03 88 Overspeed detection delay time 0.0 to 2.0 0.1 s 1.0 No
F1-10 0389 03 89 Excessive speed deviation detection
level
0 to 50 1% 10 No
F1-11 038A 03 8A Excessive speed deviation detection
delay time
0.0 to
10.0
0.1 s 0.5 No
Con-
stant
Regis-
ter num-
ber
(hex)
Class 64 (hex) Name Setting
range
Setting
unit
Default
setting
Write
during
opera-
tion
In-
stance
At-
tribute