EasyManua.ls Logo

Omron ACCURAX G5 - Page 271

Omron ACCURAX G5
553 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-5
5-1 Position Control
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
5
BASIC CONTROL Mode
The settings for command pulse rotation direction and COMMAND PULSE mode are as follows.
Pn006 Pn007
Command
pulse pattern
Signal
name
Forward direction
command
Reverse direction
command
0
0 or 2
90° phase
difference,
2-phase pulse
(phase A
+ phase B)
CW
CCW
1
Forward
direction pulse
train + Reverse
direction pulse
train
CW
CCW
3
Pulse train
+ Sign
CW
CCW
1
0 or 2
90° phase
difference, 2-
phase pulse
(phase A
+ phase B)
CW
CCW
1
Forward
direction pulse
train + Reverse
direction pulse
train
CW
CCW
3
Pulse train
+ Sign
CW
CCW
t1
t1
Phase B
t1
t1
t1
Phase A
t1
t1
t1
Phase B is 90° behind phase A.Phase B is 90° ahead of phase A.
t2
t2
t2
t2
t3
t4
t4
t5
t5
t6
L
H
t6
t6
t6
Phase B
t1
t1t1
t1
t1
Phase A
t1
t1
t1
Phase B is 90° ahead of phase A.Phase B is 90° behind phase A.
t2
t2
t2
t2
t3
t4
t5
t4
t5
t6
t6
H
L
t6
t6
Symbol
Allowable
input
maximum
frequency
Minimum required duration [μs]
t1 t2 t3 t4 t5 t6
+CWLD, -CWLD, +CCWLD,
-CCWLD
4 Mpps 0.25 0.125 0.125 0.125 0.125 0.125
+CW, -CW,
+CCW, -CCW
Line driver 500 kpps 211111
Open collector 200 kpps 5 2.5 2.5 2.5 2.5 2.5

Table of Contents

Other manuals for Omron ACCURAX G5