5-20
5-4 Internally Set Speed Control
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
5
BASIC CONTROL Mode
Selecting the Internally Set Speeds
The following tables show the internally set speeds that are set with VSEL1, VSEL2 and
VSEL3 (internally set speed selection 1, 2 and 3).
Pn300 = 1
Pn300 = 2
*1. The mode will be analog speed control.
Input the proper current to REF.
Pn300 = 3
Number VSEL1 VSEL2 VSEL3 Set speed
0 OFF OFF Disabled Pn304
1 ON OFF Disabled Pn305
2 OFF ON Disabled Pn306
3 ON ON Disabled Pn307
Number VSEL1 VSEL2 VSEL3 Set speed
0 OFF OFF Disabled Pn304
1 ON OFF Disabled Pn305
2 OFF ON Disabled Pn306
3 ON ON Disabled *1
Number VSEL1 VSEL2 VSEL3 Set speed
0 OFF OFF OFF Pn304
1 ON OFF OFF Pn305
2 OFF ON OFF Pn306
3 ON ON OFF Pn307
4 OFF OFF ON Pn308
5 ON OFF ON Pn309
6 OFF ON ON Pn310
7 ON ON ON Pn311