8-45
8-5 Interface Monitor Setting Parameters
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8
Parameters Details
Explanation of Set Values
Do not set it to a value other than a number 0 to 5, and 8 to 10.
Refer to "11-2 Warning List" (P.11-5) for more information on settings.
The set values for this parameter are same as Warning Output Selection 1 (Pn440).
Set the positioning completion range.
The set values for this parameter are same as Positioning Completion Range 1 (Pn431).
Pn439
Brake Release Speed Setting
Setting
range
30 to 3,000 Unit r/min
Default
setting
30
Power OFF
and ON
Yes
All
Released (ON)
Released (ON)
Engaged (OFF)
Engaged (OFF)
Motor rotation speed
Pn439 set value
Pn438 set value
When the motor
takes longer than
Pn438 ms to reach
Pn439 rpm
Pn438 set value
Motor rotation speed
Pn439 set value
t1
*1
t1
*1
When the motor takes
less than Pn438 ms to
reach Pn439 rpm
Pn440
Warning Output Selection 1
Setting
range
0 to 10 Unit −
Default
setting
0
Power OFF
and ON
−
All
Set
value
Explanation
0No
1 Overload warning
2 Excessive regeneration warning
3 Battery warning
4Fan warning
5 Encoder communications warning
8 Encoder overheating warning
9 External scale error warning
10 External scale communications error warning
Pn441
Warning Output Selection 2
Setting
range
0 to 7 Unit −
Default
setting
0
Power OFF
and ON
−
All
Pn442
Positioning Completion Range 2
Setting
range
0 to 262,144 Unit Command unit
Default
setting
10
Power OFF
and ON
−
Position
Full closing