177
From the moment the reset input is turned ON until the timing input is ON
and OFF for the first time after the reset input is turned OFF.
Power on
Sensing section
Scaled conver-
sion data
Input
TIMING input
Reset input

Peak-to-peak Hold If the timing hold mode is set to peak-to-peak hold, the Unit continues data sam-
pling while the TIMING input is ON.
When the TIMING input is turned OFF and the measurement mode is selected
using the data input function, the difference between the maximum value and
minimum value of the input data sampled between the leading and trailing
edge of the timing input is stored in the input word as the scaled conversion
data.
When the TIMING input is turned OFF and the comparison mode is selected
using the data input function, the comparison result flags of the input word are
turned ON or OFF according to the comparison result processed by the Unit.
The Unit stops data sampling during the following periods, The scaled conver-
sion data is BBBB.
From the moment the Unit is turned ON until the first timing input is turned
ON and OFF.
From the moment the reset input is turned ON until the timing input is ON
and OFF for the first time after the reset input is turned OFF.
Power on
Sensing section
Scaled con-
version data
Input
TIMING input
Reset input
ba
cd

Available Commands and Functions
Function (Command code)
Timing Hold
Normal Sampling Hold Maximum
Hold
Minimum Hold Peak-to-peak
Hold
Scaling Value Teach (C5*0) Yes
Command Error (Word status: E003)
Set Value Teach (C8*0) Yes
Present Value Read: BCD (CC00) Yes
Forced-zero Shift
(ZERO external control input)
Yes Yes Yes Yes Zero input will
be ignored.
Hysteresis Set (CA00)
Hysteresis Read (CB00)
Yes Commands are received, but the hysteresis function is invalid.
Timing Hold
Section 2-2

Table of Contents