8 Advanced Settings
8-20
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual
Reflectance Margin Threshold
This is to use as a threshold for driving the output. Output will be driven if grade is under the threshold.
Fixed Pattern Damage
Disabled
This will not be evaluated to drive the output.
Enabled
This will be evaluated against the corresponding threshold to drive the output.
Fixed Pattern Damage Threshold
This is to use as a threshold for driving the output. Output will be driven if grade is under the threshold.
Axial Non-Uniformity
Disabled
This will not be evaluated to drive the output.
Enabled
This will be evaluated against the corresponding threshold to drive the output.
Axial Non-Uniformity Threshold
This is to use as a threshold for driving the output. Output will be driven if grade is under the threshold.
Grid Non-Uniformity
Disabled
This will not be evaluated to drive the output.
Enabled
This will be evaluated against the corresponding threshold to drive the output.
Grid Non-Uniformity Threshold
This is to use as a threshold for driving the output. Output will be driven if grade is under the threshold.
Unused ECC
Disabled
This will not be evaluated to drive the output.
Enabled
This will be evaluated against the corresponding threshold to drive the output.
Unused ECC Threshold
This is to use as a threshold for driving the output. Output will be driven if grade is under the threshold.
Overall Grade
The overall is calculated in accordance with the ISO 15415 specification. The overall grade is the
lowest individual parameter grade seen during the individual scan.