EasyManua.ls Logo

Omron NJ301-1200 - Page 178

Omron NJ301-1200
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Error Tables
3-116
NJ-series Troubleshooting Manual (W503)
04A80000 hex Control Power Supply Undervoltage Servo G5 and G5 Linear I576, I577
04A90000 hex Overvoltage Servo G5 and G5 Linear I576, I577
04AA0000 hex Main Circuit Power Supply Undervolt-
age (Undervoltage between positive
and negative terminals)
Servo G5 and G5 Linear I576, I577
04AB0000 hex Main Circuit Power Supply Undervolt-
age (AC Cutoff Detected)
Servo G5 and G5 Linear I576, I577
04AC0000 hex Overcurrent Servo G5 and G5 Linear I576, I577
04AD0000 hex IPM Error Servo G5 and G5 Linear I576, I577
04AE0000 hex Regeneration Tr Error Servo G5 and G5 Linear I576, I577
04AF0000 hex Encoder Phase-Z Error Servo G5 I576
04B00000 hex Encoder CTS Signal Error Servo G5 I576
04B10000 hex Node Address Setting Error Servo G5 and G5 Linear I576, I577
04B20000 hex Other Errors G5 Linear I577
04BA0000 hex Connection Error between Inverter
and Communications Unit
MX2/RX-series Inverters with Ether-
CAT Communications Units
I574
04BB0000 hex Inverter Warning MX2/RX-series Inverters with Ether-
CAT Communications Units
I574
04BC0000 hex Inverter Trip MX2/RX-series Inverters with Ether-
CAT Communications Units
I574
04C40000 hex Sensor Communications Error E3X-series Fiber Sensors with Ether-
CAT Communications Unit for Digital
Sensors and EtherCAT Digital Sen-
sor Communications Units Operation
Manual
E413 and
E429
04C50000 hex Sensor Communications Has Not
Been Established
E3X-series Fiber Sensors with Ether-
CAT Communications Unit for Digital
Sensors and EtherCAT Digital Sen-
sor Communications Units Operation
Manual
E413 and
E429
04D00000 hex* Hardware Error ZW-CE1@T Confocal Fiber Type Dis-
placement Sensor
Z332
08010000 hex Battery Warning Servo G5 I576
08020000 hex Fan Warning Servo G5 and G5 Linear I576, I577
08030000 hex Encoder Communications Warning Servo G5 I576
08040000 hex Encoder/Serial Conversion Unit Over-
heating Warning
Servo G5 and G5 Linear I576, I577
08050000 hex Life Expectancy Warning Servo G5 and G5 Linear I576, I577
08060000 hex External Encoder Error Warning Servo G5 and G5 Linear I576, I577
08070000 hex External Encoder Communications
Warning
Servo G5 and G5 Linear I576, I577
08080000 hex Encoder Communications Disconnec-
tion Error
Servo G5 I576
08090000 hex Encoder Communications Error Servo G5 I576
080A0000 hex Encoder Communications Data Error Servo G5 I576
080B0000 hex Safety Input Error Servo G5 and G5 Linear I576, I577
080C0000 hex External Encoder Connection Error Servo G5 and G5 Linear I576, I577
080D0000 hex External Encoder Communications
Data Error
Servo G5 and G5 Linear I576, I577
080E0000 hex External Encoder Status Error 0 Servo G5 and G5 Linear I576, I577
080F0000 hex External Encoder Status Error 1 Servo G5 and G5 Linear I576, I577
Event code Event name Functional classification Reference

Table of Contents

Other manuals for Omron NJ301-1200