3 Error Tables
3-30
NJ-series Troubleshooting Manual (W503)
54015449 hex Circular Interpola-
tion Center Specifi-
cation Position Out
of Range
The position specified for
the center point exceeded
the allowed range when the
center method was speci-
fied for the
MC_MoveCircular2D (Cir-
cular 2D Interpolation)
instruction.
The difference
between the distance
from the start point to
the center point and
the distance between
the end point to the
center point exceeded
the permitted value
specified for the cor-
rection allowance ratio
in the axes group set-
tings when the center
designation method
was specified for the
MC_MoveCircular2D
(Circular 2D Interpola-
tion) instruction.
S NJ-series
Instruc-
tions Ref-
erence
Manual
(Cat. No.
W502)
5401544A hex Instruction Execu-
tion Error Caused
by Count Mode
Setting
An instruction that cannot
be used when the Count
Mode is set to Rotary Mode
was executed for an axis
that was set to Rotary
Mode.
An instruction that
cannot be used when
the Count Mode is set
to Rotary Mode was
executed for an axis
that was set to Rotary
Mode.
S Same as
above.
5401544C hex Parameter Selec-
tion Out of Range
The parameter specified for
the ParameterNumber
input variable to a motion
control instruction is out of
range.
Instruction input
parameter exceeded
the valid range of the
input variable.
S Same as
above.
5401544D hex Stop Method
Selection Out of
Range
The parameter specified for
the StopMode input vari-
able to a motion control
instruction is out of range.
Instruction input
parameter exceeded
the valid range of the
input variable.
S Same as
above.
5401544E hex Latch ID Selection
Out of Range for
Trigger Input Con-
dition
The parameter specified for
the TriggerInput::LatchID
input variable to a motion
control instruction is out of
range.
Instruction input
parameter exceeded
the valid range of the
input variable.
S Same as
above.
5401544F hex Setting Out of
Range for Writing
MC Setting
The parameter specified for
the SettingValue input vari-
able to a motion control
instruction is out of range.
Instruction input
parameter exceeded
the valid range of the
input variable.
The parameter specifi-
ca
tion and the data
type of the setting
value do not agree.
S Same as
above.
54015450 hex Trigger Input Con-
dition Mode Selec-
tion Out of Range
The parameter specified for
the TriggerInput:: Mode
input variable to a motion
control instruction is out of
range.
Instruction input
parameter exceeded
the valid range of the
input variable.
S Same as
above.
54015451 hex Drive Trigger Sig-
nal Selection Out
of Range for Trig-
ger Input Condition
The parameter specified for
the TriggerInput::Input-
Drive input variable to a
motion control instruction is
out of range.
Instruction input
parameter exceeded
the valid range of the
input variable.
S Same as
above.
54015453 hex Motion Control
Instruction Re-exe-
cution Disabled
(Axis Specification)
An attempt was made to
change the parameter for
the Axis input variable
when re-executing a motion
control instruction. (This
input variable cannot be
changed when re-executing
an instruction.)
A parameter for an
input variable that can-
not be changed for re-
execution was
changed.
S Same as
above.
Event code Event name Meaning Assumed cause
Level
Refer-
ence
Maj Prt Min Obs Info