7-25
7 Tag Data Link Functions
NJ-series CPU Unit Built-in EtherNet/IP Port Users Manual (W506)
7-2 Setting Tag Data Links
7
7-2-4 Creating Tags and Tag Sets
The Tag List on the left side of the dialog box shows the tags that are already registered, and the
Candidate Tag List on the right side of the dialog box shows the other tags that are not regis-
tered yet.
21
Select the tags that you want to add from the Candidate Tag List and click the Button.
You can register up to eight tags in a tag set. (If you include the Controller status in the tag set,
you can register up to only seven tags, and two bytes are added to the size.)
Data is sent and received in the order it is displayed in the tag list. To change the order of a tag,
select the tag and click the Up and Down Buttons ( ).
22
To confirm the changes, click the OK Button at the bottom of the Edit Tag Set Dialog Box.
23
Click the OK Button in the Edit Device Parameters Dialog Box.
You can create network variables in the Sysmac Studio and import these variables to the Network Con-
figurator to assign them to tags and tag sets. Use the following procedure.
z Creating Global Variables on the Sysmac Studio
1
Create a global variable with the Global Variable Editor of the Sysmac Studio and select Input or
Output for the Network Publish attribute of the variable. Save the project when you are finished.
(2) Importing Variables with a Network Publish Attribute Created on
the Sysmac Studio to the Network Configurator

Table of Contents

Related product manuals